Five servers cannot all be treated alike when one of them will eventually fail. I had to place 21 Kubernetes nodes on five machines so that losing any one piece cost as little as possible. This page gives the specifications in that order: what was there, then what each kind of failure took with it.
It is the reference page for the On-Premise Kubernetes Platform, which covers why it was designed this way. The cluster ran a multi-tenant SIEM that accepted logs from over 1,500 remote agents at 6,000–10,000 logs per second, and it held 100% uptime for the 90 days before I left Decian in March 2026.

- physical servers
- 5
- two tiers
- CPU threads
- 896
- physical RAM
- 3,523 GB
- about 3.4 TB
- Kubernetes nodes
- 21
- 3 control plane, 18 workers
- vCPUs for workloads
- 456
- RAM for workloads
- 2.67 TB
The five servers, and what ran on each
Kubernetes did not run directly on the hardware. Each server ran Proxmox, which splits a physical machine into virtual machines, and each Kubernetes node was one of those virtual machines. The servers came in two tiers.
| Server | CPU and RAM |
|---|---|
| Supermicro AS-1024US-TRT, three of them (general purpose) | 2× AMD EPYC 7532, 128 threads, 503 GB |
| Supermicro Super Server (high performance) | 2× AMD EPYC 7742, 256 threads, 1,007 GB |
| Dell PowerEdge R7525 (high performance) | 2× AMD EPYC 7763, 256 threads, 1,007 GB |
Press a server below to fail it.
- CPcontrol plane nodes 3 × 8 vCPUs, 32 GB each
- APool A workers 9 × 16 vCPUs, 96 GB each
- BPool B workers 4 × 32 vCPUs, 192 GB each
- CPool C workers 5 × 32 vCPUs, 192 GB each
All 5 running. 21 nodes, 456 vCPUs. Press a server to fail it.
General purpose 1 down. Lost: 1 of 3 control plane nodes, 3 of 9 Pool A workers (56 of 456 vCPUs). Still running: 2 of 3 control plane nodes, 6 of 9 Pool A workers, 4 of 4 Pool B workers, 5 of 5 Pool C workers.
General purpose 2 down. Lost: 1 of 3 control plane nodes, 3 of 9 Pool A workers (56 of 456 vCPUs). Still running: 2 of 3 control plane nodes, 6 of 9 Pool A workers, 4 of 4 Pool B workers, 5 of 5 Pool C workers.
General purpose 3 down. Lost: 1 of 3 control plane nodes, 3 of 9 Pool A workers (56 of 456 vCPUs). Still running: 2 of 3 control plane nodes, 6 of 9 Pool A workers, 4 of 4 Pool B workers, 5 of 5 Pool C workers.
High performance 1 down. Lost: 4 of 4 Pool B workers (128 of 456 vCPUs). Still running: 3 of 3 control plane nodes, 9 of 9 Pool A workers, 5 of 5 Pool C workers. Nothing left of: Pool B workers.
High performance 2 down. Lost: 5 of 5 Pool C workers (160 of 456 vCPUs). Still running: 3 of 3 control plane nodes, 9 of 9 Pool A workers, 4 of 4 Pool B workers. Nothing left of: Pool C workers.
Diagram as text
- General purpose 1 (2× EPYC 7532 · 128 threads · 503 GB): 1 control plane nodes, 3 Pool A workers.
- General purpose 2 (2× EPYC 7532 · 128 threads · 503 GB): 1 control plane nodes, 3 Pool A workers.
- General purpose 3 (2× EPYC 7532 · 128 threads · 503 GB): 1 control plane nodes, 3 Pool A workers.
- High performance 1 (2× EPYC 7742 · 256 threads · 1,007 GB): 4 Pool B workers.
- High performance 2 (2× EPYC 7763 · 256 threads · 1,007 GB): 4 Pool C workers, 1 Pool C workers (GPU).
If one virtual machine dies
I split each server into several smaller virtual machines on purpose. A VM can be lost to a kernel panic, a misconfiguration or a failed upgrade. If each server had run one large VM, losing it would have taken a large part of the cluster offline. With several smaller ones, a single VM failure cost a fraction of one server. In Pool A that was 1 worker of 9.
It costs overhead. More VMs means more operating systems running and more memory held back for each one’s kernel. I sized the VMs large enough to run real workloads efficiently and small enough that losing one did not cascade.
If a whole server dies
The diagram above shows each case. The three general-purpose servers each carried one control plane node and three Pool A workers, so losing one of them took 1 of 3 control plane nodes and 3 of 9 workers.
The control plane is the part of Kubernetes that decides where workloads run. It keeps its state in a store called etcd, which needs a majority of its members to agree. With three members on three different servers, a single server failure left two, and that was still a majority.
Pool B and Pool C each sat on one high-performance server. I allowed that because the workloads there carried their own redundancy, such as database replicas and distributed caches, which can lose a node.
Three pools, because workloads differ
One uniform pool would have meant over-provisioning everywhere or starving some workloads. A pool is a group of worker nodes with the same size and labels, so a workload can ask for the kind of machine it needs.
Pool A, the general-purpose pool, ran web services, background jobs and platform services. Its nodes were sized to run several medium-sized workloads each without contention.
Pool B ran latency-sensitive and memory-hungry workloads: databases, caches and search indices. NUMA was enabled on these nodes. NUMA is how a large server arranges memory around its processors, and workloads like these run better when their memory stays close to the processor using it. Larger nodes also meant fewer workloads per node, which cut down on one workload slowing another.
Pool C was the same size per node as Pool B, with one difference covered next.
The control plane nodes were small by design. They ran etcd and the Kubernetes API server and no workloads.
| Group | Nodes | Each | Total |
|---|---|---|---|
| Control plane | 3 | 8 vCPUs, 32 GB | 24 vCPUs, 96 GB |
| Pool A | 9 | 16 vCPUs, 96 GB | 144 vCPUs, 864 GB |
| Pool B | 4 | 32 vCPUs, 192 GB | 128 vCPUs, 768 GB |
| Pool C | 5 | 32 vCPUs, 192 GB | 160 vCPUs, 960 GB |
Workloads chose a pool by label. Pool A nodes were labeled workload=general-purpose, and Pool B and Pool C nodes workload=high-performance.
If a workload wants the GPU
One Pool C node had an NVIDIA A100 40GB passed through to it, meaning the virtual machine was given the physical card directly. It was used for ML inference and rendering.
That node carried a taint, nvidia.com/gpu=present:NoSchedule. A taint is a mark on a node that keeps workloads off it unless they say they can tolerate it. Without it the scheduler could have placed ordinary workloads on the GPU node and left GPU jobs short of its CPU and memory.
Where a disk came from
Storage was served by two systems. Ceph is distributed storage that ran on the same five servers and kept copies of data on more than one of them. TrueNAS is a separate storage appliance built on ZFS.
- total capacity
- 62 TiB
- OSDs
- 20
- all up and in
- monitors
- 4
- spread across hosts
- managers
- 5
- one active, the rest standby
- metadata servers
- 2 + 2
- active and standby
- objects
- 3.82M
Storage was asked for at two levels. Each virtual machine needed disks from Proxmox, and each workload needed volumes from Kubernetes. Both levels drew on the same two systems.
| Who asks, and how | Ceph | TrueNAS |
|---|---|---|
| VM disk: Ceph RBD, the default | yes | |
| VM disk: iSCSI | yes | |
| VM disk: NVMe over Fabrics | yes | |
| Kubernetes: ceph-rbd class, the default | yes | |
| Kubernetes: cephfs class, shared files | yes | |
| Kubernetes: truenas-iscsi class | yes |
Most virtual machines used Ceph RBD, a block device served by Ceph. It gave thin provisioning, snapshots and live migration with no separate storage to run for the hypervisor. A VM moved to TrueNAS only for a concrete reason: ZFS features such as compression and replication, a disk kept on a physically separate pool, or lower latency. For the few latency-sensitive VMs I used NVMe over Fabrics, which carries the NVMe command set across the network without translating it to SCSI the way iSCSI does.
Inside Kubernetes, ceph-rbd was the default class for workloads that needed their own persistent disk, such as databases. cephfs gave a shared filesystem that several workloads could mount at once. truenas-iscsi served workloads that benefited from ZFS snapshots and clones or needed a different performance profile.
Using the same two systems at both levels kept one set of dashboards and one conversation about capacity.
Versions
Kubernetes v1.32.0 on Talos v1.11.6. How the cluster was monitored is on the pipeline observability page.
Scott Tompkins